SASSuite User Manual

Version 6.25

LeCroy Corporation

57

Click on the CRC Error checkbox, and then click on the OK button at the bottom of the
screen. The Trigger/Filtering screen now shows:

Note that the Global Rules now has the event "Wait for CRC Error" listed, but since there
is no corresponding action defined, the bar at the top has changed from green to yellow
to indicate an incomplete command, and there is a yellow dot next to the incomplete
command.

To complete the command, click on the link that says "<Click here to add an action>", and
select "Trigger" from the list of available actions. The action screen now shows:

Note that you have the option to define a trigger to happen after "N" occurrences of the
event (in this case, after N CRC Errors), but for now we will leave the value at the default
setting of "1" and click the OK button.

Note: All actions have the parameter "After Nth occurrence" where N can

be set to a number greater than or equal to one. If N is set to three,
this does NOT mean that the action will happen three times.
This means that the event which calls the action must occur three
times before the action happens one time.