SASSuite User Manual

Version 6.25

LeCroy Corporation

189

Calculating Time between Frames

You can calculate time between cells within Frame Tracker by clicking on an event and
then positioning your mouse pointer over a second event and reading the ensuing tooltip.

Step 1 Click on the time value for the first event.

Step 2 Scroll down through the trace to the second event and position

the mouse pointer above its time value. A tooltip will appear
showing the time interval between the first and second events.

Hiding Traffic

You can hide Aligns, Channels and other data from the Frame Tracker window by clicking
the Hide buttons on the toolbar in the Trace window

or by

selecting one or more of the various Hide options in the Display Options dialog box.

Searching

When the Trace view and Frame Tracker windows are synchronized, the Find and Go To
options in the Search menu will apply to the Frame Tracker window. The Trace and
Frame Tracker windows can be synchronized by selecting the Synchronize button.

Zooming In and Out

Zooming out provides a high-level view of a trace. This allows users to display more
events on screen. Cell coloring can be used to distinguish between different types of
traffic on the bus.