Atapi commands, Atapi command properties dialog, Bus conditions and oob signals – Teledyne LeCroy SAS Suite User Manual User Manual
Page 119
![background image](/manuals/353605/119/background.png)
SASSuite User Manual
Version 6.25
LeCroy Corporation
109
ATAPI Commands
Individual ATAPI 6/7 commands can be selected as a trigger event. Resource limitations
restrict ATAPI triggering to a single channel and to a single ATAPI event.
ATAPI
Command
Properties
Dialog
To specify ATAPI commands as the recording event, select the command using the
Operation Code or Command name. Additional ATAPI parameters can be specified by
entering bit-level pattern in binary or decimal including LUN, transfer length and LBA.
Bus Conditions and OOB Signals
Bus Conditions and Out of Band Signals are presented in a single dialog box.
Bus
Conditions
and OOB
Signals
Select from the check boxes to specify the type of Bus Condition or OOB Signal that you
want the analyzer to search for.
If NOT is checked, any unchecked condition will generate an event match.