Front Panel LEDs (from left to right)

A PWR (power) - Green indicator LED for CATC 10K. Lights when the unit

power is switched on.

B Status indicator - Red indicator LED for CATC 10K. Lights during

initialization/power up of CATC 10K base unit. Blinks if a self-test fails.

C REC (recording) - Green LED. Lights when the unit is recording.
D TRG (triggered) - Orange LED. Lights when the unit triggers on an event.
E

UPLD (Upload) - Green LED. Lights when trace is being uploaded from the
analyzer to the PC.

F

Manual Trigger - Push-button. Allows a manual Trace capture.

G 1 - 4 (Link Channels 1 - 4) - Green LEDs. Lights when a connection is

established on the corresponding link. Blinks during OOB or when only one of
the two connected devices is transmitting.

Connectors on the SASTracer Analyzer Module

Plug-in Modules

SS002MAA-X & SS003MAA-X

use single-lane Serial ATA

Connectors (4).

Plug-in Module

SS004MAA-X

use 4 port Infiniband style connectors (1).

SASTracer/Trainer Rear Panel Description

From left to right, the CATC 10K rear panel contains the following components:

USB type “B” host computer connector

This connector links the analyzer to the Host PC. for the purpose of transmitting
commands from the PC to the analyzer and uploading traces from the analyzer’s
recording memory to the SASSuite software for viewing and analysis.

RS-232 25 pin "Data Output" Connector

This connector links a 25 pin RS-232 cable to an external breakout board. The breakout
board allows signals to be sent from the analyzer to an external device such as an
oscilloscope or from an external device to the analyzer for the purpose of triggering on
an external input. You configure input/output signalling through the Recording Options
dialog box. Breakout board use is described at the end of this chapter.