Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718115 Spirit II 275 User Manual

Page 100

Advertising
background image

Section 5: Torch Consumables and Cutting Charts

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-30

Stainless Steel - 260 Amps - H17 Plasma / Nitrogen Shield

Copper Electrode

(H17 = 17.5% Hydrogen / 32.5% Argon / 50% Nitrogen)

This gas combination gives the best cut quality and minimum dross levels

Shield Cap

Nozzle

Electrode

277211

277118

277135

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

277280

277139

279100

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

3/8

40

63

64

63

145

85

.160

.250

500

.190

1/2

142

80

.140

.300

600

5/8

145

65

.185

.350

800

.195

3/4

150

55

.225

.400

1200

1.0

160

33

.250

.450

1500

.200

1.25 ***

170

26

.280

.350

.205

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

10

40

63

64

63

144

2140

4.0

6.5

600

4.8

12

142

2060

3.7

7.3

16

145

1640

4.7

8.9

800

5.0

20

151

1315

5.8

10.3

1500

25

159

875

6.3

11.3

5.1

32 ***

170

650

7.1

8.7

5.2

Marking* – For All Material Thicknesses

Type of Gas

Preflow Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

108

250

6350

.100 2.5 .100 2.5

0

Argon** Nitrogen**

N/A

50

25

N/A

75

100

2540

.160 4.1 .100 2.5

0

* Use an arc transfer height (ignition height) of .250” (6.4 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

*** Edge start recommended.

(Revised 04/26/2013)