Spirit II User’s Manual

Section 5: Torch Consumables and Cutting Charts

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-1

Section 5: Torch Consumables and

Cutting Charts

Installing / Removing the Torch Head

WARNING: Remove primary power from the Spirit system!

1. Each time the torch head is connected to the torch base, use a cotton swab to apply

a small amount of o-ring lubricant on each of the seven o-rings on the top of the

torch head.

Reminder: do not use an excessive amount of o-ring lubricant.

2. Align the indicator on the torch head (circle) with the one on the torch base (slot).
3. Apply enough upward force to engage the threads while tightening the attachment

ring. Turn the attachment ring to the RIGHT to tighten.

4. Keep tightening the attachment ring until it stops. There should be no gap between

the attachment ring and the o-ring on the torch base.
During this process, a small amount of coolant will collect in the torch head.

It is normal for this coolant to discharge between the o-ring on the torch base and

the attachment ring while the system is being pressurized. If coolant continues to

discharge after the system is pressurized, turn off the plasma power supply, remove

the torch head and inspect the o-rings for damage.

YES

NO!

To remove the torch head, turn the attachment ring to the LEFT.

There is no

gap between

o-ring and

attachment

ring

Gap is visible

between

o-ring and

attachment

ring

O-ring

O-ring

Torch Base

Torch Head