Appendix B: Serial Communication

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

B-8

Command

# Hex String

Additional Information

Restore Factory

Condition

47 AA nn FA 2F 00 01 0D Restores the factory cutting condition for the

present material type and thickness.

Cutting Condition

Type

48 AA nn FA 30 00 -- 0D

If requested in command #30, the system will

transmit whether the present cutting condition is a

factory default setting or a custom user setting.

Note: This is only valid when initially loading

material type, thickness, and process.

0 = factory / 1 = custom

Configure H17

Cutting

49 AA nn FA 31 00 -- 0D

0 = Disable H17 cutting

1 = Enable H17 cutting

Reload Cutting

Condition

50 AA nn FA 32 00 01 0D

Reloads the cutting conditions for the present

material type and thickness

Set Arc Off Delay

Time

51 AA nn FA 33 -- -- 0D

Sets the delay time in mS between the reception

of a stop signal and the extinction of the arc.

Valid Range: 0 to 2000 mS

Machine Type

52 AA nn FA 34 -- -- 0D

If requested in command #30, the system will

transmit the machine type.

153 = Spirit150a

203 = Spirit200a

273 = Spirit275a

403 = Spirit400a

Set Marking Arc

Voltage

53 AA nn FA 35 -- -- 0D

Sets marking arc voltage in Volts x 100

Valid Range: 5000 to 20000

Set Marking Height

54 AA nn FA 36 -- -- 0D

Sets marking height in mils (inches / 1000)

Valid Range: 0 to 999

Set Marking Start

Height

55 AA nn FA 37 -- -- 0D

Sets marking start height in mils (inches / 1000)

Valid Range: 0 to 999

Set Marking Travel

Speed

56 AA nn FA 38 -- -- 0D

Sets marking travel speed (inches / min)

Valid Range: 0 to 999

Set Marking Pierce

Time

57 AA nn FA 39 -- -- 0D

Sets marking pierce time in ms

Valid Range: 0 to 9999

Configure

Cut/Mark/Cut

59 AA nn FA 3B 00 -- 0D

0 = Local at power supply

1 = Hard signal via interface plug

2 = RS-422

Node Focus

254 AA C8 FA FE 00 nn 0D Sends a global command to all systems and sets

the node focus to system nn