Spirit II User’s Manual

Section 4: Operation with Automatic Gas Console

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

4-1

Section 4: Operation

Operating the Plasma Console

The Plasma Console is the touch screen interface to the entire Spirit system when the

Automatic Gas Console (AGC) is used instead of the Manual Gas Console (MGC).

OFF Button

Push to disable the Spirit system.

Release (turn to the right) to enable

the system, which can then be

energized using the ON Button.

Touch Screen

Turns on automatically when AC

power is applied to the Spirit system.

Press the screen to operate as

described below.

Navigation and ON Button

Press the navigation buttons to access the various screens described in this section.

Change settings by simply pressing that part of the screen.

Navigation Buttons

Press to access the desired screen.

ON Button

Press to energize the system (the

OFF Button must be released first).
This button also indicates three

different system conditions:

The system is ON; cooling fans

and coolant pump are running.

The system is OFF. Press to turn

the system ON.

The system is OFF, but enabled

(OFF Button has been released).

Press to turn the system ON.