Error codes – Lincoln Electric 718115 Spirit II 275 User Manual

Page 127

Advertising
background image

Spirit II User’s Manual

Section 6: Maintenance &Troubleshooting

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

6-7

Error Codes

The following is a comprehensive list of error codes for the Spirit system. When the system

uses a Manual Gas Console, only the numeric error code is displayed. When an Automatic

Gas Console is used, the text description is also displayed.

Power Supply

Code Short Description

Long Description

10121 ISC Door

ISC Door is open

10138 Stop Pressed (Off Button)

OFF Button on Plasma Console or Manual Gas

Console is pressed.

10140 Phase R

Transformer Secondary phase voltage is low

10150 Phase Y

Transformer Secondary phase voltage is low

10160 Phase B

Transformer Secondary phase voltage is low

10161 CON1

Main Contactor failed to open

10170 Coolant Level

Coolant Level is low

10180 Coolant Flow Low

Coolant flow is low

10190 Coolant Flow High

Coolant flow is high

10220 Coolant Temperature High

The coolant temperature is high

10290 GC Quiet

Lost CAN communication with Gas Console

10300 PC Quiet

Lost CAN communication with Plasma Console

10320 FCC Invalid

Final Cut Current invalid

10330 PAC Invalid

Pilot Arc Current invalid

10340 AH IHS Timeout

Arc Hold for Initial Height Sense has timed out

10350 PAT Not Established

Pilot Arc Current not established within 2 seconds

10360 TAC Not Established

Transferred Arc Current not established within 2

seconds

10370 Current Unbalanced

Current is not balanced between chopper

assemblies (275A and 400A systems)

10380 TAC Lost 1

Transferred Arc lost during TAC hold time

10390 TAC Lost 2

Transferred Arc lost during Upslope

10400 TAC Lost 3

Transferred Arc lost during Cutting

10410 TAC Lost 4

Transferred Arc lost during Downslope

10420 FCC Unreached

Did not achieve final cut current

10430 Output Over Current

Chopper has exceeded its maximum rated current

10432 Output Over Current TZ

Instantaneous Over Current detected

10440 Output Over Voltage

Maximum Cutting Voltage has been exceeded.

10450 Start Premature Removal

Start Signal removed prior to completion of upslope

10461 Chopper1 Temp

Chopper 1 maximum operating temperature

exceeded

10462 Chopper2 Temp

Chopper 2 maximum operating temperature

exceeded

10463 Chopper3 Temp

Chopper 3 maximum operating temperature

exceeded

Advertising