Appendix B: Serial Communication

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

B-4

RS-422 Serial Commands

Note: In the following commands, “nn” represents the net node of the power supply that is to

receive the command. To send a global command to all power supplies in a network

configuration, “nn” should be set to C8 hex (200 decimal). The “-- --” in the hex string is the MSB

followed by the LSB of a type int. The integer is the value found in the additional information

column.

Command

# Hex String

Additional Information

Set Material Type

1 AA nn FA 01 00 -- 0D

00 = Mild Steel – Hot Rolled

01 = Stainless Steel

02 = Aluminum

03 = Other

04 = Mild Steel – Cold Rolled

Set Thickness

2 AA nn FA 02 -- -- 0D

Thickness in mils (inches x 1000)

Valid Range: 0 to 2000

Set Operating

Current

3 AA nn FA 03 00 -- 0D

01 = 30A

02 = 50A

03 = 70A

04 = 100A

05 = 150A

06 = 200A

0A = 260A

0B = 275A

0C = 400A

Set Cutting Pierce

Time

4 AA nn FA 04 -- -- 0D

Cutting pierce time in ms

Valid Range: 0 to 9999

Set Preflow

Pressure

6 AA nn FA 06 -- -- 0D

Preflow psi x 10

Valid Range: 0 to 1200

Set Plasma Gas

Type

7 AA nn FA 07 00 -- 0D

00 = Oxygen

02 = Air

04 = H17

Set Plasma

Pressure

8 AA nn FA 08 -- -- 0D

Plasma psi x 10

Valid Range: 0 to 1200

Set Shield Gas Type 9 AA nn FA 09 00 -- 0D

00 = Oxygen

01 = Nitrogen

02 = Air

Set Shield Pressure 10 AA nn FA 0A -- -- 0D

Shield psi x 10

Valid Range: 0 to 1200

Cutting Travel

Speed

15 AA nn FA 0F -- -- 0D

If requested in command #30, the system will

transmit the cutting travel speed in inches per

minute. Range: 0 to 999