Lincoln Electric 718115 Spirit II 275 User Manual

Page 130

Advertising
background image

Section 6: Maintenance &Troubleshooting

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

6-10

Problem

Possible Cause

Primary power has been

applied to the system, but

the plasma console screen is

blank

1. Check power/communications CAN cable

connection on back of plasma console.

2. Check for blown DIN rail fuse.

3. Check for 120v on pins of power/communications

CAN cable at back of plasma console.

The plasma console screen

is on, but the touch screen

doesn't work

1. Cycle primary power to the Spirit system.

Gas pressures will not adjust

properly

1. Wrong consumables installed in torch.

2. Loose pressure transducer cable on PC board in

the AGC.

3. Check connectors on the AGC valve associated

with the malfunction.

Low pressure error

1. Supply gas pressure(s) less than 120 psi.

Pressure error during cut

1. Supply gas pressure(s) fluctuating during cut.

Advertising