Spirit II User’s Manual

Section 3: Installation

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

3-9

ISC Control Cable and ISC Ground Connections

Perform the following steps to connect the ISC control cable and ISC ground. See

Figure 5 on the next page.
ISC Control Cable

1. Connect the ISC control cable plug labeled P16 to the connector labeled P16 on the

rear of the power supply.

2. Connect the ISC control cable plug labeled P1 to the connector labeled P1 on the

impulse start console.

ISC Ground Cable

1. Connect one end of the ISC ground cable to the ground stud on the impulse start

console.

2. Connect the other end of the ISC ground cable to the star ground on the cutting

table. Make sure that good metal-to-metal contact is made.

Cooling System Connections

Perform the following steps to connect the cooling system to the impulse start console.

See Figure 5 on the next page.
Coolant Supply Hose

1. Connect one end of the coolant supply hose to the coolant out fitting on the rear of

the power supply. Note that the coolant out fitting has right hand threads.

2. Connect the other end of the coolant supply hose to the coolant in fitting on the

impulse start console. Note that the coolant in fitting has right hand threads.

Coolant Return Hose

1. Connect one end of the coolant return hose to the coolant in fitting on the rear of the

power supply. Note that the coolant in fitting has left hand threads.

2. Connect the other end of the coolant return hose to the coolant out fitting on the

impulse start console. Note that the coolant out fitting has left hand threads.

5

6

7