Appendix B: Serial Communication

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

B-1

Appendix B: Serial Communication

Initializing the Spirit System

The Spirit system uses an RS-422 serial communication port located on the rear of the

plasma console to receive and respond to commands that are transmitted from an x/y

controller. The communications ground is isolated to prevent ground loops. System

initialization is simple. Apply power, wait until the plasma console has finished booting,

then transmit the desired material type, material thickness, and optionally the process

(cutting or marking) and the system will be ready for operation. All other parameters will

be set to their default values and may be changed at any time.

Transmitting Parameters to the

Spirit System

To transmit parameters to the Spirit, convert the following hex strings to 8 bit binary

arrays (AA = 10101010) and transmit them using a 9600 baud RS-422 serial

communication port. The port settings should have a start bit, one stop bit, and no

parity. A table can be found in this section that lists the RS-422 commands and their

descriptions. This table contains the necessary hex strings for sending different

commands and parameters to the system. For example, to switch the material type

from mild steel to stainless steel, look up the command for setting material type in the

table. You will see the following table entry:

Command

# Hex String

Additional Information

Set Material Type

1 AA nn FA 01 00 -- 0D 00 = Mild Steel – Hot Rolled

01 = Stainless Steel

02 = Aluminum

03 = Other

04 = Mild Steel – Cold Rolled

Note that spaces in the command string are shown for clarity only and should not be

sent as part of the command. A command string always begins with the value AA hex.

The “nn” is the net node (communication node) of the Spirit system that is to receive the

command. The net node value of a system is set via the Set Communication Node

selection on the maintenance screen. See Section 4 for detailed information on setting

the net node. The value FA hex is the Spirit identifier. The value 01 hex is the value

that signifies the Set Material Type command. The value 0D hex is the end of

command character. In the above example, the following hex string would need to be

transmitted to switch the material type to stainless steel for a Spirit system on node 1:

AA 01 FA 01 00 01 0D

To send a parameter, the parameter value needs to be sent as part of the command.

For example, to send a desired cutting pierce time of 1000 milliseconds to the system,