Cnc machine interface connections – Lincoln Electric 718115 Spirit II 275 User Manual

Page 44

Advertising
background image

Section 3: Installation

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

3-20

CNC Machine Interface Connections

Perform the following steps to properly interface the Spirit system with a CNC cutting

machine. See the system schematic for additional information.
Plasma Start Input

The power supply requires a contact closure between P8 pins 3 and 4 to commence the

cutting or marking sequence. The sequence is terminated when the contacts are

opened. The contacts should be rated for 24VDC - 7.3mA.
Plasma Cut/Mark Input

The power supply requires a contact closure between P8 pins 1 and 2 to put the system

in plasma marking mode. Opening the contacts puts the system in cutting mode. The

operating mode should be selected prior to applying a start signal. The contacts should

be rated for 24VDC - 7.3mA.
Arc Hold Input

The power supply requires a contact closure between P8 pins 10 and 11 to inhibit arc

starting even though a plasma start signal has been applied to the unit. When the

contacts are opened, the arc is initiated. This feature is used to decrease cycle time by

allowing pre-cut gas and contact sequencing to occur simultaneously with initial torch

height positioning. The contacts should be rated for 24VDC - 7.3mA.
Motion Output

The power supply provides a maintained contact closure output between P8 pins 12

and 14 as long as an arc is maintained between the torch and the workpiece. The

motion contacts are rated for 24VDC – 10mA.
Remote On/Off Input

The power supply requires a maintained contact closure between P8 pins 5 and 6 to

energize the system from a remote location, provided that the OFF Button on the

Plasma Console is released. Opening the contacts deenergizes the system. If the

remote on/off feature is not used, install a jumper between terminal block TB1 positions

7 and 8. The contacts should be rated for 24VAC – 10mA.
Power Supply Ready Output

The power supply provides a maintained contact closure output between P8 pins 7 and

8 when the system is ready to cut or mark. The contacts are open during gas purge or

when an error occurs. The contacts are rated for 24VDC – 10mA.
RS-422 Serial Communication Link

An RS-422 serial communication link can be connected between the plug on the rear of

the plasma console and a CNC machine or automatic height control system. All

process parameters can be controlled via the RS-422 communication link. Also, cutting

or marking information such as initial height, cutting or marking height, recommended

arc voltage, and recommended travel speed can be transmitted from the plasma

console to the CNC machine or height control. See Appendix B for additional serial

communication information.