Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718115 Spirit II 275 User Manual

Page 101

Advertising
background image

Spirit II User’s Manual

Section 5: Torch Consumables and Cutting Charts

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-31

Stainless Steel - 275 Amps - Air Plasma / Nitrogen Shield

Copper Electrode

This gas combination gives medium cut quality and minimum dross levels

Shield Cap

Nozzle

Electrode

277263

277276

277270

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

277266

277258

279100

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/2

20

73

70

75

143

120

.125

.300

600

.165

5/8

148

90

.140

.350

800

3/4

152

80

.180

.400

1200

.170

1.0

165

55

.210

.450

1500

1.25 ***

175

35

.250

.350

.180

1.50 ***

185

25

.300

.350

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

12

20

73

70

75

141

3220

3.1

7.3

600

4.2

16

148

2275

3.6

8.9

800

20

153

1940

4.7

10.3

1500

4.3

25

164

1435

5.2

11.3

32 ***

175

880

6.4

8.9

4.6

38 ***

184

640

7.5

8.9

Marking* – For All Material Thicknesses

Type of Gas

Preflow Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

108

250

6350

.100 2.5 .100 2.5

0

Argon** Nitrogen**

N/A

50

25

N/A

55

100

2540

.130 3.3 .100 2.5

0

* Use an arc transfer height (ignition height) of .250” (6.4 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

** Edge start recommended.

(Revised 04/26/2013)