Section 4: Operation with Automatic Gas Console

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

4-14

Advanced Config Tab

Press the Config navigation button followed by the Advanced Config tab to access the

screen described below.

Set RS422 Node

When multiple Spirit systems are being used together on an RS-422 serial

communication link, each system must have a unique identification number (node

number) to identify itself to the network. To set the communication node number,

simply choose from node 1 through 8.

When using an Inova torch height control system with the Spirit, the communication

node feature must be disabled. To disable the communication node, press the Disabled

button.

Set CAN Domain

Make sure the CAN domain is set to 1. All other selections are for future use.

Allow Error Suppression

Press Enable to allow error suppression. Press Disable to stop error suppression.

Arc Off Delay

In some instances, such as when cutting thicker stainless steel materials, it may

be desirable to delay the extinction of the cutting arc after a stop signal is

received. To program an arc off delay, press the data entry button ( ) and enter

the desired delay time in milliseconds. The delay can be set from 0 to 2000 mS.