5-35

Aluminum - 100 Amps - Air Plasma / Nitrogen Shield

Copper Electrode

Shield Cap

Nozzle

Electrode

277286

277284

277282

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

277151

277283

279100

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/4

25

80

26

80

158

105

.155

.250

300

.095

3/8

162

90

.180

.275

400

.098

1/2

165

70

.195

.300

500

.100

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

6

25

80

26

80

158

2710

3.8

6.3

300

2.4

10

162

2210

4.6

7.0

500

2.5

12

165

1890

4.9

7.4

Marking* – For All Material Thicknesses

Type of Gas

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

130

250

6350

.100 2.5 .100 2.5

0

Argon**

Air**

N/A

50

25

N/A

71

100

2540

.120 3.0 .100 2.5

0

* Use an arc transfer height (ignition height) of .250” (6.4 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.