Imperial, Metric, Marking* – for all material thicknesses – Lincoln Electric 718115 Spirit II 275 User Manual

Page 115

Advertising
background image

Spirit II User’s Manual

Section 5: Torch Consumables and Cutting Charts

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-45

Stainless Steel - 200 Amps - Air Plasma / Nitrogen Shield

Silver Electrode

Shield Cap

Nozzle

Electrode

277274

279489

279440

(yellow o-ring)

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

277266

279443

279060

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/4

20

74

58

72

130

200

.070

.200

400

.150

3/8

133

150

.250

500

1/2

140

110

.115

.300

600

.152

5/8

146

75

.150

.350

800

.155

3/4

153

60

.190

.400

1200

1.0

158

40

.210

.450

1500

.160

1.25 ***

170

20

.250

.350

.165

1.50 ***

180

10

.275

.350

.175

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

6

20

74

58

72

129

5220

1.8

4.9

400

3.8

10

134

3655

1.9

6.5

600

12

138

3020

2.6

7.3

3.9

16

146

1890

3.8

8.9

800

20

153

1450

4.8

10.3

1500

25

157

1050

5.2

11.3

4.1

32 ***

170

495

6.4

8.9

4.2

38 ***

179

260

6.9

8.9

4.4

Marking* – For All Material Thicknesses

Type of Gas

Preflow Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

120

250

6350

.100 2.5 .100 2.5

0

Argon** Nitrogen**

N/A

50

25

N/A

70

100

2540

.100 2.5 .100 2.5

0

* Use an arc transfer height (ignition height) of .200” (5.1 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

*** Edge start recommended.

(Revised 04/26/2013)

Advertising