Customizing Cutting or Marking Settings

Changes to any of these factory default settings will cause the Setup message at the

top of the screen to change from

Setup: Optimum

to

Setup: Custom - Not Saved

. See

the next section to save custom settings.

Altering the Current Set Point

To alter the current set point from the

default setting, press the Current

(Amps) button on the Material Screen

and choose from the list of available

values.

Note: When marking is the selected

process, the current cannot be

changed.

Altering Gas Types

On the Material Screen, press the

Plasma or Shield button and select the

desired gas type.

The plasma gas can be changed to Air,

Oxygen, Nitrogen, or H17. Shield gas

can be changed to Air, Oxygen, or

Nitrogen.

Preflow gas cannot be changed.

Altering Gas Pressures

Normally, the preflow gas and plasma

gas pressures should not be changed.

The shield gas can be adjusted in small

increments to fine-tune a cut. Use the

data entry button to enter a desired

pressure. Note that all of the gases

have minimum and maximum limits

and cannot be programmed beyond

these limits.