Section 5: Torch Consumables and Cutting Charts

Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

5-36

Aluminum - 150 Amps - Air Plasma / Nitrogen Shield

Copper Electrode

Shield Cap

Nozzle

Electrode

277117

277293

277292

Outer Cap

Retaining Cap

Swirl Ring

Torch Head

284150

277152

277139

279100

Imperial*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(in)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm)

(in)

(in)

(msec)

(in)

1/4

20

71

50

69

145

145

.130

.250

400

.125

3/8

155

115

.185

.275

500

1/2

165

90

.230

.300

600

.130

5/8

170

65

.250

.325

800

.135

3/4

45

.350

1200

.140

Metric*

Material

Thickness

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Cutting

Height

Pierce

Height

Pierce

Time

Kerf

Width

(mm)

(psi)

(psi)

(psi)

(psi)

(volts)

(mm/m)

(mm)

(mm)

(msec)

(mm)

6

20

71

50

69

143

3770

3.1

6.3

400

3.2

10

156

2825

4.8

7.0

600

12

162

2430

5.5

7.4

3.3

16

170

1630

6.4

8.3

1200

3.4

20

170

990

9.0

3.6

Marking* – For All Material Thicknesses

Type of Gas

Preflow

Plasma

Shield

Postflow

Arc

Voltage

Travel

Speed

Marking

Height

Initial

Height

Pierce

Time

(Plasma) (Shield)

(psi)

(psi)

(psi)

(psi)

(volts)

(ipm) (mm/min) (in) (mm) (in) (mm) (msec)

Nitrogen Nitrogen

N/A

25

25

N/A

135

250

6350

.100 2.5 .100 2.5

0

Argon**

Air**

N/A

50

25

N/A

69

100

2540

.100 2.5 .100 2.5

0

* Use an arc transfer height (ignition height) of .250” (6.4 mm) for cutting and .100” (2.5 mm) for marking.

** Only available on systems with the Automatic Gas Console.

(Revised 04/26/2013)