Spirit II User’s Manual

Section 3: Installation

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

3-17

Gas Supply Connections

Perform the following steps to connect the gas supply lines to the AGC. See Section 2

for gas supply requirements. Mating hose barbs and connectors are supplied with the

system and are sized for 3/8 inch inside diameter hose.

Do not change the inlet gas

supply fittings to quick-connect fittings. Using quick-connect fittings to connect

and disconnect pressurized hoses may cause damage to the system.

Note: When making hose connections, only tighten the brass fittings enough to

make gas seals. The fittings are subject to damage if over tightened.

Air Inlet (ISO 3821 hose color - black)

Air must be supplied to the unit at all times, regardless of the cutting current or

material type.

Oxygen Inlet (ISO 3821 hose color - blue)

Oxygen must be supplied to the unit at all times, unless stainless steel is being cut

with H17 plasma.

Nitrogen Inlet (ISO 3821 hose color - black)

Nitrogen must be supplied to the unit at all times, regardless of the cutting current or

material type.

H17 Inlet (ISO 3821 hose color - red)

H17 must be supplied to the unit when stainless steel is being cut with H17 as the

plasma gas. See cutting charts in Section 5 for more information.

Argon Inlet

Argon is optional and provides improved marking capabilities. If not used, this inlet

should be capped.