Spirit II User’s Manual

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

3-2

2-Gang Manifold

The 2-gang manifold assembly must be mounted to the torch. See Section 2 for

mounting dimensions.

Torch

The torch must be installed on the positioner of an arc voltage control (height control)

capable of maintaining the cutting arc voltage within 1 arc volt. The arc voltage must be

adjustable in 1 arc volt increments. The positioner must be rigid to ensure cut quality

and a torch collision sensor is highly recommended. See Section 2 for mounting

dimensions.

System Interconnection

The Spirit II system interconnection diagrams on the following pages will assist in the

planning and installation of the system as well as identifying cables and hoses upon

receipt.

The optional Inova torch height control is also shown to assist with its connections,

whether as an external console or internal to the plasma power supply.