Default cutting parameters, Troubleshooting serial communication – Lincoln Electric 718115 Spirit II 275 User Manual

Page 165

Advertising
background image

Spirit II User’s Manual

Appendix B: Serial Communication

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

B-3

Default Cutting Parameters

In order to initialize parameters on a Spirit system an external device must

communicate, in sequence, the material type, material thickness, process (cutting or

marking) and the cutting current. Once the Spirit system receives the cutting current, all

other parameters will be set to their default values. Whenever the material type,

material thickness, process or cutting current is changed, new default values will be

retrieved for all other parameters. If a changed is desired, cutting current must be sent

last for the updated to occur, To use non-standard parameters, first set the material

type, material thickness, process and cutting current (in sequence), and then set the

remaining parameters (i.e. Pierce time) to the desired values.

Troubleshooting Serial Communication

When troubleshooting serial communication with the Spirit system, switch to the View

Serial Communication Screen to view incoming and outgoing data. See Section 4 for

information on the RS-422 Tab.