10.10 Flame proof and dust proof IECEx certified

RAMC (/EF1)

10.10.1 Technical data

Certificate :

IECEx IBE12.0007

Flame proof :

Ex d IIC T1-T6 Gb

Dust proof :

Ex tb IIIC TX Db

Max. surface temperature TX :corresp. process temperature

Housing :

Painted aluminium casting, type 91

Output signal (with electronic transmitter -E or -H) :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20 mA (3- wire unit)

Power supply (with electronic transmitter -E or -H) :

2- or 3- wire unit

Limit switches:

Options /K1 to /K10 possible

Ambient temperature :

-20 °C to 60 °C

Minimum process temperature :

-20°C

Threads for cable glands :

- M20x1.5 (standard)

- ½” NPT (option /A5)

Degree of protection :

IP66 / 67

Temperature classification for gas application :

Temperature class

Standard

On extension (option /A16) On extension (option /A16)

and thermal insulation

T6

85°C

85°C

85°C

T5

100°C

100°C

100°C

T4

120°C

135°C

135°C

T3

120°C

200°C

200°C

T2

120°C

300°C

300°C

T1

120°C

370°C

350°C