Yokogawa RAMC User Manual

Page 80

Advertising
background image

<9. TECHNICAL DATA>

9-8

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

ELECTRONIC TRANSMITTER

Attention :
The maximum ambient temperature of the transmitter or of the
limit switches according to the temperature class may not be
exceeded because of heat transmission from the medium.
Table 6 Entity parameters of electronic transmitter

Ui

[V]

Ii

[mA]

Pi

[W]

C

i[nF]

Li

[mH]

Tamax

[°C]

KS1/2/3

30

101

1.4

4.16

0.15

70

ES1/2/3

30

101

1.4

4.16

0.15

70

KN1

30

152

1.4

4.16

0.15

70

FS1/CS1

30

100

1.4

40

0.15

70

NS1

30

101

1.4

4.16

0.15

70

Intrinsically safe electronic transmitter 4 - 20mA

(with/without HART-communication) with ATEX-

certification (option /KS1) :

Certificate :

PTB 12ATEX 2003

Output signal :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20mA (3- wire unit)

Explosion proof :

Ex ia IIC T6 Gb; group II ; category 2G

Entity parameter :

see table 6

Intrinsically safe electronic transmitter Profibus PA -

communication with ATEX- certification (option /KS1) :

Certificate:

PTB 96ATEX 2160X

Output signal :

Profibus PA

Explosion proof :

Ex ia IIB/IIC T4; group II; category 2G

Table 7 Entity parameters

IIC

IIB

FISCO IIB/IIC

Ui

24V

17.5V

acc. IEC 60079-27

Ii

250mA

280mA

Li

negligible small

negligible small

Ci

negligible small

negligible small

Electronic transmitter 4 - 20mA (with/without

HART-communication) type “n” (non incendive)

acc. EN 60079-15 for category 3 (option /KN1) :

Output signal :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20mA (3- wire unit)

Explosion proof :

Ex nL IIC T6 protection „nL”; group II ; category 3G

Dust proof :

Ex II 3D; group II ; category 3D

Max. surface temperature : 80°C

Entity parameter :

see table 6

Intrinsically safe electronic transmitter 4 - 20mA

(with/without HART-communication) with

IECEx- certification (option /ES1) :

Certificate :

IECEx PTB 12.0020

Output signal :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20mA (3- wire unit)

Explosion proof :

Ex ia IIC T6 Gb; group II ; category 2G

Entity parameter :

see table 6

Intrinsically safe electronic transmitter 4 - 20mA

(with/without HART-communication) with ATEX-

or IECEx- certification for use in category 3G

(option /KS3 or /ES3) :

Output signal :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20mA (3- wire unit)

Explosion proof :

Ex ic IIC T6 Gc; group II ; category 3G

Entity parameter :

see table 6

Intrinsically safe / non incendive electronic

transmitter with FM - certification (USA + Canada)

(USA: option /FS1; Canada: option /CS1) :

Certificate :

No. : 3027471

Output signal :

4–20 mA (2-wire unit)

Explosion proof :

Intrinsic safe Cl. I, Div. 1, GP. A, B, C, D T6

Intrinsic safe Cl. 1, Zone 0, AEx ia IIC T6

Non incendive Cl. I, Div. 2, GP. A, B, C, D T6

Entity parameter of electronic transmitter :

see table 6

Intrinsically safe electronic transmitter with
KOSHA- certification (Korea)

Option /ES1 must be selected.
Same data as for IECEx certification.

Intrinsically safe electronic transmitter with
PESO- certification (India)

Option /KS1 must be selected. PESO- certificate is available
at your Yokogawa Sales Office.

Intrinsically safe RAMC with NEPSI- certification

(China) (option /NS1) :

Certificate :

GYJ0101551

Output signal :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20mA (3- wire unit)

Explosion proof :

Ex ia IIC T6

Max. Tamb. :

70°C

Entity parameter of electronic transmitter :

see table 6

Limit switches :

option /K1 to /K10

Entity parameter of limit switches :

see certificate NEPSI GYJ06542X