<10. EXPLOSION-PROTECTED TYPE INSTRUMENTS>

10-7

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

Rota Yokogawa

D-79664 Wehr

WT-MAG Mat. No. 16-8040

Serial No, xxxxxxxx

Ex ic IIC T6 Gc

Ui=30V Ii=101mA Pi=1.4W

Li=0.15mH Ci=4.16nF

II 3G

Intrinsic safe power supply for the electronic transmitter :
The power supply for the electronic transmitter may not be installed in the hazardous area, and it may not exceed
the safety relevant maximum values for voltage, current and power of the electronic transmitter as specified above.

Intrinsic safe power supply for the limit switches :
The power supply (transmitter relay) for the limit switches may not be installed in the hazardous area, and it may
not exceed the safety relevant maximum values for voltage, current and power of the connected limit switch as
specified above.