1 technical data, 1 technical data -4, Ii 3 g ii 3 d – Yokogawa RAMC User Manual

Page 96

Advertising
background image

<10. EXPLOSION-PROTECTED TYPE INSTRUMENTS>

10-4

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

10.3 Nonincendive components for Category 3 (ATEX) (/KN1)

10.3.1 Technical data

RAMC with option /KN1 have an electronic transmitter and / or limit switches with protection type "n" (non incen-
dive) for category 3G or dust proof for category 3D.

Identification:

II 3 G

II

3

D

Data of electronic transmitter :
The electronic transmitter is an apparatus with the type of protection “nL”.
It can be mounted or installed in the hazardous areas of zone 2 (category 3).
The classification in brackets is given according to the new EU regulation 94/9/EG (ATEX).
This version is identically constructed as intrinsically safe (ia) version.

Type of protection

: Ex nL IIC T6 X

n = Nonincendive

L = energy limited apparatus

Ambient temperature

: -25 °C < T

a

< 70 °C


Safety relevant maximum values :

Maximum voltage

: U

i

= 30 V

Maximum current (IIC) : I

i

= 152 mA

Maximum current (IIB)

: I

i

= 379 mA

Maximum power

: P

i

= 1.4 W

Internal inductance

: L

i

= 0.15 mH

Internal capacity

: C

i

= 4.16 nF

Maximum surface temperature for dust application : 80°C

Data of limit switches :
The limit switches are apparatus with the type of protection “nL”.
They can be mounted or installed in the hazardous areas of zone 2 (category 3).
The classification in brackets is given according to the new EU regulation 94/9/EG (ATEX ).
This versions are identically constructed as the corresponding intrinsically safe (ia) versions.

Type of protection

: EEx nL IIC T6 X

n = Nonincendive

L = energy limited apparatus

Ambient temperature

: -25 °C < T

a

< 100 °C for SC3,5-N0 (Standard)

-40 °C < T

a

< 100 °C for SJ3,5-SN / S1N (Fail safe)

Maximum surface temperature for dust application : 112°C

Maximum safety parameters see table 10.1.
See also specification sheet from Pepperl & Fuchs for SC3,5-N0 (Standard) and SJ3,5-SN / S1N (Fail safe).

Advertising