6.2.1 Selection of indication function (F11)

The function F11 selects the display’s indication function.
The following indications can be set: flow rate, totalizer, % value or temperature.

At the factory the display is preset to totalizer indication.

Description

Selection

Key

Indication

Change to setting mode

Enter

Display mode
F1-

Setting function

Selection
or

or

or

Flow rate
Totalizer

%

Temperature

Enter
Enter
Enter

Enter

2 x →

Enter

3 x →

Enter

F11
F11 -1
F11
F11 -2
F11
F11 -3
F11
F11 -4
F11

Back to display mode

F1-
Display mode

Note: If you press “↑” instead of “Enter”, you can return from the selected point to the previous menu without

activating the displayed parameter.

When selecting “Flow rate” the measuring unit is set with function F12 and F13. When selecting “Totalizer” the
measuring unit is set with F12. If % indication is selected, F12 and F13 have no effect. The internal totalizer is
updated, if “Flow rate” or “Counter” is selected. In case of setting to “%” the internal counter is not updated
and keeps its previous value.
If "Temperature" is selected the unit can be set by function F15. The indicated value is the temperature in the
indication unit.
After changing the indicating function and measuring units the corresponding measuring unit label should be
fixed on the right side next to the display.