Yokogawa RAMC User Manual

Page 82

Advertising
background image

<9. TECHNICAL DATA>

9-10

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

FLAME PROOF AND DUST PROOF RAMC

Flame proof and dust proof RAMC with ATEX-

certificate (option /KF1):

Certificate :

IBExU 05 ATEX 1086

Flame proof :

Ex d IIC T1 ... T6 Gb ; group II ; category 2G

Dust proof :

Ex tb IIIC TX Db IP6X; group III ; category 2D

Max. surface temperature TX :corresp. process temperature

Housing :

Painted aluminium casting, type 91

Output signal (with electronic transmitter -E, -H) :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20 mA (3- wire unit)

Power supply (with electronic transmitter -E, -H) :

2- or 3- wire unit

Limit switches :

Options /K1 to /K10 possible

Ambient temperature :

-20 °C to 60 °C

Minimum process temperature :
-20°C

Threads for cable glands :

- M20x1.5 (standard)

- ½” NPT (option /A5)

Temperature classification :

Table 8

see table 8

Flame proof and dust proof RAMC with IECEx-

certificate (option /EF1):

Certificate :

IECEx IBE12.0007

Flame proof :

Ex d IIC T1 ... T6 Gb ; group II ; category 2G

Dust proof :

Ex tb IIIC TX Db IP6X; group III ; category 2D

Max. surface temperature TX :corresp. process temperature

Housing :

Painted aluminium casting, type 91

Output signal (with electronic transmitter --E, -H) :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20 mA (3- wire unit)

Power supply (with electronic transmitter -E, -H ) :

2- or 3- wire unit

Limit switches :

Options /K1 to /K10 possible

Ambient temperature :

-20 °C to 60 °C

Minimum process temperature :
-20°C

Threads for cable glands :

- M20x1.5 (standard)

- ½” NPT (option /A5)

Temperature classification :

Table 8

see table 8

Flame proof and dust proof RAMC with NEPSI-

certificate (China) (option /NF1) :

Certificate :

GYJ071430

Flame proof :

Ex d IIC T6

Dust proof :

DIP A20 TA T1 - T6 IP67

Max. surface temperature TA: corresponding process

temperature

Housing :

Painted aluminium casting type 91

Output signal (with electronic transmitter -E or -H) :

4–20 mA (2- wire unit, 3- wire unit) ; 0-20 mA (3- wire unit)

Power supply (with electronic transmitter -E or -H) :

2- or 3- wire unit

Limit switches :

Options /K1 to /K10 possible

Ambient temperature :

-20 °C to 60 °C

-20 °C to 55 °C (for use in zone 20)

Minimum process temperature :
-20°C

Threads for cable glands :

- M16x1.5 (standard)

- ½” NPT (option /A5)

Temperature classification :

Table 8

Temp.

class

Max. Process temperature

No extension

On Extension

On extension

with insulation

T6

85°C

85°C

85°C

T5

100°C

100°C

100°C

T4

120°C

135°C

135°C

T3

120°C

200°C

200°C

T2

120°C

300°C

300°C

T1

120°C

370°C

350°C

Flame proof and dust proof RAMC with PESO-

certificate (India) :

Option /KF1 must be selected. PESO- certificate is available
at your Yokogawa Sales Office.

Flame proof and dust proof RAMC with KOSHA-

certificate (Korea):

Same data as IECEx- certified type (/EF1).

Advertising