3 standard specifications, 3 standard specifications -4 – Yokogawa RAMC User Manual

Page 76

Advertising
background image

<9. TECHNICAL DATA>

9-4

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

9.3 Standard Specifications

MEASURING TUBE

Materials of wetted parts :

- Stainless steel AISI 316L (1.4404)

- PTFE

- Other materials on request

Fluids to be measured :

suitable for a variety of liquids, gas and steam

Measuring range :

See table 11 and 12

Measuring range ratio :
10:1

Process connections / Stainless steel :

- Flanges :

- acc. EN1092-1

DN100 – DN150 PN16

DN15 – DN100 PN40

DN50 – DN80 PN63

DN15 – DN50 PN100

- acc. ASME B 16.5

½” – 6“ Class 150 raised face

½” – 6“ Class 300 raised face

½” – 3“ Class 600 raised face

Roughness of sealing

Form B1 :

RA 3.2 - 6.3

Form B2 :

RA 0.8 - 3.2

ASME :

RA 3.2 - 6.3

-Threaded connection :

- male acc. DIN 11851

- NPT- female

- G- female

- Clamp acc. DN25 / 1“ – DN100 / 4“

Process pressure :
Depends on process connection, see table 10 to 12

higher pressure (up to 700 bar) on request

Process temperature :

- medium wetted parts made of stainless steel

: -200 …+370 °C

- medium wetted parts made of PTFE

: -80 … +130 °C

See fig. 7a to 7c

Measuring accuracy :

Table 1

Material of
wetted parts

Size

Measuring accuracy
acc. Directive VDI/
VDE 3513 sheet 2
(q

G

=50%)

SS

DN 15 - 100

1.6%

SS

DN 125 - 150

2.5%

PTFE

DN 15 -100

2.5%

Heat tracing

Pressure Equipment Directive (PED) Directive 97/23/EG :

Tubes :

- Modul

: H

- Fluid Group : 1 (dangerous fluids)

- Produced acc. to category

: III

- Classification : Table 6 (piping)


Heating (options /T1 to /T6) :

- Art. 3 section 3 : (Volume < 1L)

- Fluid Group : 2 (non-dangerous fluids)

- Classification : Table 2 (vessels)

CANADIAN REGISTRATION NUMBERS (CRN ) available

upon request

Installation :

- Mounting direction : vertical

- Flow direction

: upwards

- Mounting length : see tables 10, 12, 13, 14

- Straight pipe inlet length

: DN 80/100 at least 5D, not

necessary for smaller sizes

Weight :

See table 15

LOCAL INDICATOR

(Indicator/Transmitter Code -T)

Principle :
The indication is made by magnetic coupling of a magnet
enclosed in the float and a magnet in the indication unit,
which follows the movements of the float, with a pointer.

Indicator housing :

- Materials : - Stainless steel (1.4301 / 304)

(housing type 90)

- painted aluminium casting

(housing type 91)

each with safety-glass window

- Degree of protection :

- IP66/67

Scales :

- Standard : removable aluminium plate with scale

(double scale as option)

- Marking :

direct readable units or percentage of Qmax.

Transportation- and Storage condition :

-40°C to +110°C

ELECTRONIC TRANSMITTER

(Indicator/Transmitter Code -E, -H, -G, -J)

Standard type (Code -E) :

Power supply :

- 4- wire units with galvanic isolation :

- 230 V AC +10 %/-15 %, 50/60 Hz,

fuse 0.063 A, time lag, (5x20) mm

- 115 V AC +10%/-15 %, 50/60 Hz,

fuse 0.125 A, time lag, (5x20) mm

- 2/3- wire units : - U = 14 V ... 30 V DC

Output signal :

- 4- wire units :

- 0 - 20 mA, 4 – 20 mA

- pulse output (option /CP)

max. frequency 4 Hz see fig. 3-5

- 3- wire units :

0 - 20 mA, 4 - 20 mA

- 2- wire units : 4 - 20 mA

The 20 mA point is selectable between 60% and

100% of Qnom.

Load resistance :

- 4- wire units :

≤ 500 Ω

- 2/3- wire unit : ≤ (U - 14 V) / 20 mA, max. 500 Ω

HART- communication type (Code -H, -J) :

Power supply :

- 2-wire units : U = 14 V ... 30 V DC

Output signal :

- 2- wire units :

4 – 20 mA

Load resistance :

- HART-version : 250 … 500 Ω

Profibus PA - communication type (Code -G) :

- 2- wire bus connection not polarity sensitive : 9 ... 32 V DC

acc. to IEC 61568-2 and FISCO model

- Basic current : 14 mA

- Failure current (FDE) : 10 mA additional to basic current

- Transmission rate : 31.25 kBaud

- AI block for volume flow or mass flow

- Configurable with PDM DD

- Supports I&M- functions

Advertising