<9. TECHNICAL DATA>

9-7

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

HAZARDOUS AREA SPECIFICATIONS

Overview hazardous area certified instruments:

Location

Europe

Global

USA

Canada

India

Korea

China

Certificate

ATEX

IECEx

FM

FM

PESO KOSHA

NEPSI

Electronic transmitter (WT-MAG)

Protection

ia

ic

nL

ia/tb

ia

ic

ia/tb

IS/Nl

IS/Nl

ia

ia

-

Option

/KS1

/KS3

/KN1

/KS2

/ES1

/ES3

/ES2

/FS1

/CS1

/KS1

/EF1

-

Comments

*2)

*1)

*2)

*1)

*3)

*3)

*4)

-

See page

6

6

6

9

6

6

9

6

6

6

6

-

Limit switches

Protection

ia/iaD

ic

nL

ia/tb

ia

-

ia/tb

IS/Nl

IS/Nl

-

-

ia

-

Option

/KS1

/KS3

/KN1

/KS2

/ES1

-

/ES2

/FS1

/CS1

-

-

/NS1

-

Comments

*2)

*1)

-

*1)

*5)

*6)

-

-

-

See page

7

7

7

9

7

-

9

7

7

-

-

7

-

RAMC indicator

Protection

d/tb

-

d/tb

-

-

-

d

d/tb

ia

d/DIP

Option

/KF1

-

/EF1

-

-

-

/KF1

/EF1

/NS1

/NF1

Comments

*7)

-

*7)

-

-

-

*4)

*7)

See page

8

-

8

-

-

-

8

8

6

8

Power supplies for intrinsic safe components (see page 9-9)

Option /UT

yes

yes

yes

yes

no

no

yes

Option /W1A,B

yes

yes

yes

yes

yes

yes

no

Option /W2A,B

yes

yes

yes

yes

yes

yes

no

Option /W4A,B

yes

yes

yes

yes

yes

yes

yes

Option /W2E,F

yes

yes

no

no

no

no

no

Option /W4E,F

yes

yes

no

no

no

no

yes

Notation

IS = intrinsic safe; Nl = non incendive; DIP = dust ignition proof

Comment *1)

Dust proof by RAMC housing

Comment *2)

For use in category 3G

Comment *3)

Same certification for USA and Canada

Comment *4)

PESO certificate available from Yokogawa Sales Office

Comment *5)

Only for USA; power supply free selectable

Comment *6)

For USA and Canada; power supply must be option /WxA or /WxB (x=1 or 2 or 4)