2 general description, 3 principle of measurement, 2 general description -4 – Yokogawa RAMC User Manual

Page 12: 3 principle of measurement -4

Advertising
background image

<1. INTRODUCTION>

1-4

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

1.2 General description

This manual describes installation, operation and maintenance of the RAMC. Please read it carefully before using
this device.
Further, please note that customer features are not described in this manual. When modifying specifications,
construction or parts, this manual is not necessarily revised unless it can be assumed that these changes will
impair RAMC functions or performance.
All units are thoroughly tested before shipping. Please check the received units visually to ensure that they
have not been damaged during transport. In case of defects or questions please contact your nearest
YOKOGAWA service centre or sales office. Please describe any defect precisely and indicate model code as
well as serial number.
YOKOGAWA refuses any liability for units which have been repaired by the user without prior consent and do
not meet the specifications as a consequence.

1.3 Principle of measurement

The RAMC is a Variable Area Flow Meter for volume and mass measurements of gases and liquids.
A float, whose movement is nearly independent of viscosity is guided concentrically in a specially shaped cone.
The position of the float is transferred magnetically to the indicator, which shows the measurement values by a
pointer on a scale. The indicator can be equipped with limit switches and an electronic transmitter.

Fig. 1-1

All units are calibrated with water by the manufacturer. By adjusting the calibration values to the measured
substance’s state of aggregation (density, viscosity), the flow rate scale for each measuring tube can be
determined.
Indication units can be exchanged without impairment of precision. However, the scale for the tube must be
mounted on the new indicator (and in case of an electronic transmitter the calibration EEPROM, too).

F10.EPS

Advertising