<7. HART-COMMUNICATION>

7-13

IM 01R01B02-00E-E 10th edition January 01, 2013 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

7.4.3 Basic-Setup Menu

Device setup

Basic setup

Tag

Tag Number (8 characters)

Flow unit

Flow measurement unit

Temp unit

Temperature measurement unit

Set

damping

Obtained

damping

Long tag

Long Tag Number (24 characters)

7.4.4 Detailed-Setup Menu

Device setup

Detailed setup
Characterize meter

Details on the measuring tube.

Snsr unit

Flow measurement unit in accordance with scale

Scale USL

Upper sensor limit related to flow

Snsr s/n

Serial number of the measuring tube

Final assy no.

Number of final assembly

MS Code

Ordering code of the device

Device setup

Detailed setup
Configure signal

Flow damping

Flow damping Read damping value

Set damping

0.25s/1.00s/5.00s/10.00s

Device setup

Detailed setup
Configure signal

Flow unit table

EU/US

Read preset unit set (see chapter 6-2-2)

Device setup

Detailed setup
Configure signal

Flow

unit

select

Selectable flow units:

EU

US

Cum/h

Cum/h

L/h

NmlCum/h

NmlCum/h

Kg/h

NmlL/h

StdCuFt/h

MetTon/h

CuFt/h

Kg/h

Lton/h

StdCuFt/h

Lb/h

ImpGal/h gal/h

Cum/min Cum/min

L/min

NmlCum/min

NmlCum/min

Kg/min

NmlL/min

StdCuFt/min

MetTon/min

CuFt/min

Kg/min

Lton/min

StdCuFt/min

Lb/min

ImpGal/min

gal/min