<4. Installation>

4-1

IM 01C50E01-01EN

4. Installation

4.1 Precautions

• Before installing the transmitter, read the

cautionary notes in section 2.4, “Selecting the

Installation Location.”

• For additional information on the ambient

conditions allowed at the installation location,

refer to subsection 10 “General Specifications.”

NOTE

To connect this transmitter to the Field Wireless

Network, information for connecting to the field

wireless devices needs to be set beforehand.

Refer to subsection 6.4 “Connecting to the Field

Wireless Network.”

IMPORTANT

• When performing on-site pipe fitting work

that involves welding, use care to prevent

outflow of the welding current into the

transmitter.

• Do not use the transmitter as a foothold for

installation.

4.2 Mounting

• The mounting bracket shown in Figure 4.1 is

used for the transmitter and is installed on 50A

(2-inch) pipe. It can be installed either on a

horizontal pipe and a vertical pipe or on a wall.

• To install the mounting bracket on the

transmitter, torque the transmitter fastening bolt

(1) to about 20 to 30 N m.

Advertising