<10. General Specifications>

10-3

IM 01C50E01-01EN

Table 10.1

Sensor type, measurement range, and accuracy

Sensor Type

Standard

Measurement Range

Accuracy

T/C

B

IEC584

100 to 300°C ( 212 to 572°F )

± 5.0°C ( ± 9.0°F )

300 to 400°C ( 572 to 752°F )

± 2.0°C ( ± 3.6°F )

400 to 1820°C ( 752 to 3308°F )

± 1.5°C ( ± 2.7°F )

E

-200 to 1000°C ( -328 to 1832°F )

± 0.4°C ( ± 0.8°F )

J

-200 to 1200°C ( -328 to 2192°F )

± 0.5°C ( ± 0.9°F )

K

-200 to 1372°C ( -328 to 2502°F )

± 0.6°C ( ± 1.1°F )

N

-200 to 1300°C ( -328 to 2372°F )

± 0.6°C ( ± 1.1°F )

R

-50 to 100°C ( -58 to 212°F )

± 1.7°C ( ± 3.1°F )

100 to 1768°C ( 212 to 3214°F )

± 0.8°C ( ± 1.5°F )

S

-50 to 100°C ( -58 to 212°F )

± 1.7°C ( ± 3.1°F )

100 to 1768°C ( 212 to 3214°F )

± 0.8°C ( ± 1.5°F )

T

-200 to 400°C ( -328 to 752°F )

± 0.5°C ( ± 0.9°F )

RTD

Pt100

IEC751

-200 to 850°C ( -328 to 1562°F )

± 0.3°C ( ± 0.6°F )

Pt200

-200 to 850°C ( -328 to 1562°F )

± 0.6°C ( ± 1.1°F )

Pt500

-200 to 850°C ( -328 to 1562°F )

± 0.5°C ( ± 0.9°F )

mV

-

-10 to 100 [mV]

*1

-10 to 220 [mV]

*2

± 0.03 [mV]

Ohm

-

0 to 2000 [Ω]

± 1 [Ω]

Note: For T/C input, add Cold Junction Compensation Accuracy (± 0.5°C) to the total accuracy.

For RTD input of the 2-wire connection, add a corrected value (± 0.1°C) to the total accuracy.

*1:

Applicable for amplifier housing code 7.

*2:

Applicable for amplifier housing code 8 and 9.

Table 10.2

Effects of ambient temperature

Sensor Type

Temperature Effects per 1.0°C Change in Ambient

Temperature

Measurement Range

T/C

B

0.2°C - ( 0.066% of ( t - 100 ) )

100°C ≤ t < 300°C

0.07°C - ( 0.0057% of ( t - 300 ) )

300°C ≤ t < 1000°C

0.037°C

t ≥ 1000°C

E

0.0035°C - ( 0.00492% of t )

t < 0°C

0.0035°C + ( 0.00146% of t )

t ≥ 0°C

J

0.0039°C - ( 0.00529% of t )

t < 0°C

0.0039°C + ( 0.00149% of t )

t ≥ 0°C

K

0.00521°C - ( 0.00707% of t )

t < 0°C

0.00521°C + ( 0.00182% of t )

t ≥ 0°C

N

0.0077°C - ( 0.00918% of t )

t < 0°C

0.0077°C + ( 0.00136% of t )

t ≥ 0°C

R, S

0.04°C - ( 0.057% of t )

t < 0°C

0.04°C + ( 0.0102% of t )

0°C ≤ t < 100°C

0.0316°C - ( 0.001% of t )

100°C ≤ t < 600°C

0.0175°C + ( 0.00173% of t )

t ≥ 600°C

T

0.00513°C - ( 0.00631% of t )

t < 0°C

0.00513°C + ( 0.0008% of t )

t ≥ 0°C

RTD

Pt100

0.0048°C + ( 0.0016% of absolute value t )

Entire Sensor Input Range

Pt200

0.0038°C + ( 0.0015% of absolute value t )

t < 650°C

0.0028°C + ( 0.0016% of t )

t ≥ 650°C

Pt500

0.003°C + ( 0.0014% of absolute value t )

t < 650°C

0.002°C + ( 0.0016% of t )

t ≥ 650°C

mV

0.2μV + ( 0.0015% of reading )

Entire Sensor Input Range

Ohm

0.001Ω + ( 0.0011% of reading )

Entire Sensor Input Range

Note1:

The “t” on Table 10.2 means the value of the reading in °C.

Note2:

The “absolute value t” on Table 10.2 means the absolute value of the reading in °C.

[ Example of absolute value t ]

When the temperature value is 250 Kelvin, abs reading is 23.15, absolute (250 - 273.15).