<9. Parameter Summary>

9-6

IM 01C50E01-01EN

Object

ID

Attribute

ID

Label

Description

Default value Handling

5.

AI1 block

6.

AI2 block

*2

(continued)

103

Cal Point Lo

Sets the zero-point adjustment for the input adjustment (zero-

gain adjustment ) of the sensor.

Be sure to perform adjustment with Cal Point Lo (zero-point)

first.

---

W

104

Cal Point Hi

Sets the gain-point adjustment for the input adjustment (zero-

gain adjustment) of the sensor.

---

W

105

Cal Point Clear

Resets the input adjustment value of the sensor to the factory

setting.

0

W

106

Process Value

Type

Selects data to output to PV.Value.

0. % value after the scaling process is performed

1. Actual target value after the filter process is performed

0

W

107

Reference

Junction Unit

Sets the unit for Reference Junction Temp and External

Reference Junction Value.

Select any of °C (Celsius), K (Kelvin), °F (Fahrenheit), and °R

(Rankine).

°C

W

108

Burn Out Type

*2

Sets the burnout of the PV value at the detection.

0: The direction specified by hard ware switch

1: Set to higher side

2: Set to lower side

0

W

(Note) R: Read only, W: Read and Write

(Note) “Factory NAMUR category” refers to the four categories (C: Check function, M: Maintenance required, F: Failure, and O: Off

specification) according to NAMUR NE107.

*1:

NAMUR NE107 “Self-Monitoring and Diagnosis of Field Devices”

*2:

Applicable for dual input type with detachable antenna, Amplifier housing code 8 and 9.

*3:

Applicable for single input type with integral antenna, Amplifier housing code 7.