Spectra Precision Survey Pro v4.6 Ranger User Manual User Manual

Page 148

Advertising
background image

User’s Manual – Conventional Mode

138

field.

5. In the Sequence field, specify if you want to perform Direct Only

shots to each known point or Direct and Reverse shots.

6. Tap Solve… after each field is correctly

filled in. A new screen will open where you
can shoot a resection point.

7. Enter the name of the point that you plan

to shoot in the Resect Point field.

8. If you are shooting more than two resection

points, you have the option of taking
Distance and Angle

measurements with

each shot or Angle Only measurements by
making the appropriate selection from the
Option

pull-down menu.

Note: The Angle Only option allows you to perform all shots without
the use of a prism, but the resulting occupy point that is computed
will not have an elevation associated with it.

9. With this screen filled in correctly, aim toward the next resection

point and tap the Take Shot… button to shoot the specified
resection point.

10. Repeat Steps 7 through 10 until every resection point is shot.

After the final shot is completed, the Save Point screen will open

where you can specify a description for the new point.

11. Tap to return to the Resection screen. You can tap the Results

tab to view information about the stored point or the Map tap to
see a graphical representation of the resection.

Advertising