Spectra Precision Survey Pro v4.6 Ranger User Manual User Manual

Page 273

Advertising
background image

GPS Module

263

11. If you are not happy with the solution residual or misclosure

values for any point, you can change the control points used by
tapping in the H and/or V columns. This will change Next> to

Solve>. Tap Solve> to recalculate the solution and update the

residual / misclosure display.

12. When you are happy with the solution quality, tap Next> to

review the parameters.

13. Examine the scale and rotation values to verify they are

reasonable. See the explanation of localization parameters (Page

264) to determine what is reasonable.

14. When you are happy with the solution, tap Accept to set the

horizontal and/or vertical adjustment. The Adjust with Projection

wizard will open to show you a preview of the changes to the
geodetic points. Tap Accept to update the coordinate system in
the job and raw data, and to apply the adjustment to the points.

Manual Entry of Parameters

Manual entry of parameters is used when you already know the

appropriate horizontal and vertical localization parameters for a site.

Use manual entry of parameters to key in the site parameters and set
it as the current coordinate system.

1. Tap Solve Localization to open the Solve Localization wizard and

then tap Manual Entry>.

2. Enter the Scale, Rotation, Translations, and Origin of the

horizontal system.

Advertising