Spectra Precision Survey Pro v4.6 Ranger User Manual User Manual

Page 203

Advertising
background image

Leveling

193

13. If shooting a point that already exists,

the Point Exists screen will open.

If you are not shooting your closing
benchmark, tap Overwrite to overwrite
the existing point with the new
computed elevation, or tap Use Next to
store the benchmark as a new point.
You will then return to the Level screen

and will not continue with the following

steps.

If you are closing your level loop to this benchmark, tap

Close Loop By Existing Point to continue.

14. The next screen will prompt you to take the necessary shots

as described in Step 7. Take the shots and store the
observation to continue.

If you are not closing your level loop, you will return to the
Level screen in Step 6. If you are closing your level loop,

continue to the next step.

15. The Close Loop screen will open and

display all the information about the
loop. If you tap Close Level Loop , the
loop will be closed and no more shots
for that loop can be taken. You will

then return to the Level screen and all
the shot buttons will be grayed out.

Note: Once a level loop is closed, no additional
shot data can be added to it.

Advertising