Mounting to rotary actuators, Mounting to rotary actuators 25 – Badger Meter SRD/SRI Valve Positioners User Manual

Page 25

Advertising
background image

Mounting to Rotary Actuators

Applicable to rotary actuators that meet the VDI/VDE 3845

standard for mounting Installation position of positioner:

Mount the positioner so that the pneumatic connections

are in the same direction as the longitudinal drive axis of the

actuator as shown in

Figure 28

Figure 28: Mounting to rotary actuator

MPORTANT

I

The feedback shaft 9 of the SRD has no mechanical stop,

therefore, it may spin around. The permissible rotation angle

range is between +50 and –50 degrees around the arrow at

the housing concerning the flat area of the feedback shaft

(see

“Mounting Dimensions, Direct Mounting”

). Since a rotary

actuator has a rotary angle of about 90 degrees, the mounting

the following mounting procedure must be followed.

Attach the positioner to the actuator using the rotary

adaptor kit EBZG -R
Either of the side outputs I (or I and II) is used and the rear

output I is closed by means of the lock screw 522 588 013

Pneumatic connections: Do not use Teflon tape for sealant

The fine fibers could disturb the function of the SRD Use only

Loctite® #243 for sealant and apply it only to male threads
Screw-type glands for electrical connections are used as

needed Any unused threaded holes are closed by plugs

PREVENT ACCUMULATION OF WATER IN THE

INSTRUMENT IN THIS MOUNTING POSITION BY SEALING

CABLE ENTRY AGAINST WATER. PROVIDE A CONTINUOUS

SUPPLY OF DRY INSTRUMENT AIR.

Preparation of Positioner
Valve must be in a failsafe position and the direction of

rotation of the actuator drive shaft must be known These

items are extremely important for proper functioning These

items can be checked as follows in case they are not clear:
• In the single-acting actuator the force of the installed

springs closes The pressureless actuator is in failsafe

position Through manually feeding compressed air it can

be seen whether the actuator drive shaft rotates to the

left or to the right In the powerless SRD is y1 pressureless

• In the double-acting actuator without spring reset both

air chambers are basically equal Failsafe position can be

either “open” or “close” Therefore, indication of the failsafe

position has to be determined by engineering Then

the direction of rotation may be determined by manual

feeding of compressed air In the powerless SRD is y1

pressureless and y2 under pressure

Bolt 2 is screwed into actuator drive shaft 1 for subsequent

centering of the rotary adaptor 3 The attachment console is

mounted to the stroke actuator (see

Figure 27

and

Figure 28

)

Figure 29: Attachment diagram for bracket

Page 25

Mounting to Linear Actuators

August 2014

POS-UM-00009-EN-02

Advertising