6 Parameterisation

BU 0020 GB-2612

59

6.1.3 Information

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter set

Pos: 86 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P740

– Prozessdaten Bus In [SK 300E, SK 7x0E] @ 1\mod_1335791131327_388.docx @ 25024 @ @ 1

P740

[-01]

...

[-06]

Process data Bus In

(Process data bus in)

SK 300E /

SK 7x0E

S

0000 ... FFFF (hex)

This

parameter

informs

about the actual control
word and the setpoints that
are transferred via the bus
systems.

For display, a BUS system
must be selected in P509

Series SK 300E:

[-01 ] = Control word

Series SK 7x0E:

[-01 ] = Control word

[-02] = setpoint value 1
[-03] = setpoint value 2
[-04] = setpoint value 3

[-02] = setpoint value 1
[-03] = Setpoint value 1 High
byte
[-04] = setpoint value 2
[-05] = setpoint value 3

[-05] = Bus I/O In Bits (P480)

[-06] = Bus I/O In Bits (P480)

Pos: 87 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P741

– Prozessdaten Bus Out [SK 300E / SK 7x0E] @ 1\mod_1335791437905_388.docx @ 25048 @ @ 1

P741

[-01]

...

[-06]

Process data Bus Out

(Process data bus out)

SK 300E /

SK 7x0E

S

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

Series SK 300E

[-01] = Status word

Series SK 7x0E

[-01] = Status word

[-02] = Actual value 1
[-03] = Actual value 2
[-04] = Actual value 3

[-02] = Actual value 1
[-03] = Actual value 1 High
byte
[-04] = Actual value 2
[-05] = Actual value 3

[-05] = Bus I/O Out Bit (P481)

[-06] = Bus I/O Out Bit (P481)

Pos: 88 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P745

– Baugruppen Version [SK 300E] @ 1\mod_1335791798489_388.docx @ 25072 @ @ 1

P745

Module version

(Module version)

SK 300E

0.0 ... 3276.7

Version status (software version) of the technology unit (SK TU2-xxx), but only when own
processor is present, i.e. not for SK TU2-CTR.

Have this data available if you have a technical query.

Pos: 89 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P745

– Baugruppen Version [SK 7x0E] @ 1\mod_1335792003777_388.docx @ 25096 @ @ 1

P745

[-01]

...

[-03]

Module version

(Module version)

SK 7x0E

S

0000 ... FFFF (hex)

Version status (software version) of the installed option
module(s) but only when own processor is present, i.e. not for
SK TU1-CTR.

Have this data available if you have a technical query.

[-01] = Technology unit

[-02] = Customer unit

[-03] = Special extension unit

Pos: 90 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P746

– Baugruppen Zustand [SK 300E] @ 1\mod_1335792492116_388.docx @ 25120 @ @ 1

Advertising