PROFIBUS DP

– Supplementary manual options for NORD - Frequency Inverters

60

BU 0020 GB-2612

P746

Module status

(Module status)

SK 300E

S

0000 ... FFFF (hex)

Shows the actual status (readiness, error, communication) of the technology unit (SK TU2-xxx),
but only when own processor is present, i.e. not for SK TU2-CTR.

Example:

0603

hex

High byte = 06

hex

 Profibus

Low byte = 03

hex

 Module ready + connection to master

Details of the codes specific to the bus can be found in the section "Error monitoring" of the
relevant supplementary instructions.

Pos: 91 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P746

– Baugruppen Zustand [SK 7x0E] @ 1\mod_1335792880284_388.docx @ 25144 @ @ 1

P746

[-01]

...

[-03]

Module status

(Module status)

SK 7x0E

S

0000 ... FFFF (hex)

Shows the actual status (readiness, error, communication) of
the installed technology unit(s) (if active), but only when own
processor is present, i.e. not for SK TU1-CTR.

Example:

0603

hex

High byte = 06

hex

 Profibus

Low byte = 03

hex

 Module ready + connection to master

Details of the codes specific to the bus can be found in the
section "Error monitoring" of the relevant supplementary
instructions.

[-01] = Technology unit

[-02] = Customer unit

[-03] = Special extension unit

Pos: 92 /Anleitungen/Bussysteme/5. Parametrierung/BUS Parameter SK 5xxE @ 1\mod_1336378272615_388.docx @ 25201 @ 2 @ 1