6 Parameterisation

BU 0020 GB-2612

63

6.2.2 Extra functions

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter set

Pos: 99 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P507

– PPO-Typ @ 0\mod_1328091974415_388.docx @ 11042 @ @ 1

P507

PPO-Type

(PPO-Type)

1 ... 4

{ 1 }

This parameter can only be used with the technology unit Profibus, DeviceNet or InterBus.

See also the relevant section of the corresponding supplementary BUS manual.

Pos: 100 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P508

– Profibus-Adresse @ 0\mod_1328092017167_388.docx @ 11065 @ @ 1

P508

Profibus address

(Profibus address)

1 ... 126

{ 1 }

Profibus address, only with the technology unit Profibus

See also the additional description for the Profibus control BU 0020

Pos: 101 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P509

– Quelle Steuerwort @ 0\mod_1328092104264_388.docx @ 11088 @ @ 1

P509

Source Control Word

(Source control word)

0 ... 10

{ 0 }

Selection of the interface via which the FI is controlled.

0 = Control terminals or keyboard control ** with the ControlBox (if P510=0), the

ParameterBox (not ext. p-box) or via BUS I/O Bits.

1 = Only control terminals , the FI can only be controlled via the digital and analog inputs or

via the bus I/O Bits.

2 = USS control word *, the control signals (enable, direction of rotation, ...) are transferred

via the RS485 interface. The setpoint is transferred via the analog input or the fixed
frequencies.
Above SK 540E this setting should also be selected if communication via Modbus RTU is
intended. The frequency inverter automatically detects whether this is a USS protocol or
a Modbus protocol.

3 = CAN control word *

4 = Profibus control word *

5 = InterBus control word *

6 = CANopen control word *

7 = DeviceNet control word *

8 = Ethernet TU*** control word*

9 = CAN Broadcast *

10 = CANopen Broadcast *

*) Keyboard control (ControlBox, ParameterBox, PotentiometerBox) is blocked,

parameterisation is still possible.

**) If the communication during keyboard control is interrupted (time out 0.5 sec),

the FI will block without an error message.

***) The Ethernet TU setting must be used for all NORD Ethernet-based bus systems (e.g.:

EtherCAT: SK TU3-ECT, PROFINET: SK TU3-PNT).

Note:

Parameterisation of a frequency inverter via a field bus connection requires
parameter (P509) "Control Terminals" to be set to the appropriate bus system

Pos: 102 /Anleitungen/5. Parametrierung/Parameter/P500-P599/Parameter P510

– Quelle Sollwerte @ 0\mod_1328092251176_388.docx @ 11111 @ @ 1

NOTE:

For details about the respective Bus systems please
refer to the respective Options descriptions.

BU 0020 = Profibus

BU

0050

=

USS,

Modbus RTU

BU 0060 = CAN/CANopen

BU 0070 = InterBus

BU 0080 = DeviceNet

BU 0090 = AS-Interface

BU 0570 = EtherCAT

BU 0590 = ProfiNet

-