PROFIBUS DP

– Supplementary manual options for NORD - Frequency Inverters

68

BU 0020 GB-2612

P741

[-01]

...

[-13]

PZD bus out

(Process data bus out)

up to SK 535E

S

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

[-01] = Status word

Status word, source from
P509.

[-02] = Actual value 1 (P543)
[-03] = Actual value 2 (P544)
[-04] = Actual value 3 (P545)

[-05] = Bus I/O Out Bit (P481)

The displayed value depicts
all Bus In bit sources linked
with OR.

[-06] = Parameter data Out 1
[-07] = Parameter data Out 2
[-08] = Parameter data Out 3
[-09] = Parameter data Out 4
[-10] = Parameter data Out 5

Data during parameter
transfer.

[-11] = Actual value 1 leading
function
[-12] = Actual value 2 leading
function
[-13] = Actual value 3 leading
function

Actual value of leading
function P502/P503.

Pos: 116 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P741

– Prozessdaten Bus Out [ab SK 540E] @ 0\mod_1328177956772_388.docx @ 13382 @ @ 1

P741

[-01]

...

[-23]

PZD bus out

(Process data bus out)

SK 540E and

above

S

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

[-01] = Status word

Status word, source from
P509.

[-02] = Actual value 1 (P543 [-01])
[-03] = Actual value 2 (P543 [-02])
[-04] = Actual value 3 (P543 [-03])
[-05] = Actual value 4 (P543 [-04])
[-06] = Actual value 5 (P543 [-05])

[-07] = Bus I/O Out Bit (P481)

The displayed value
depicts all Bus In bit
sources linked with OR.

[-08] = Parameter data Out 1
[-09] = Parameter data Out 2
[-10] = Parameter data Out 3
[-11] = Parameter data Out 4
[-12] = Parameter data Out 5

Data during parameter
transfer.

[-13] = Actual value 1 leading function
[-14] = Actual value 2 leading function
[-15] = Actual value 3 leading function
[-16] = Actual value 4 leading function
[-17] = Actual value 5 leading function

Actual value of leading
function P502/P503.

[-18] = PLC status word

Status word via PLC

[-19] = Actual value 1 PLC
[-20] = Actual value 2 PLC
[-21] = Actual value 3 PLC
[-22] = Actual value 4 PLC
[-23] = Actual value 5 PLC

Actual value data via PLC