PROFIBUS DP

– Supplementary manual options for NORD - Frequency Inverters

74

BU 0020 GB-2612

7.3.2 Process data, SK 5xxE

1st word

2nd word

3rd word

4th word

PZD area with

1x16 bit setpoint

STW
ZSW

SW1

IW1

PP0 type
1,3

PZD area with up to 3

16 bit

setpoints

STW
ZSW

SW1

IW1

SW2

IW2

SW3

IW3

PP0 type
2,4

Note: 32-Bit setpoints consist of High and Low words (16-Bit each).

Note

The SK 54xE frequency inverter can administer 5 setpoint or actual values. However,
the Profibus bus system can only process setpoint or actual values 1 ... 3 (PPO1 ...
PPO4).