2 bus parameters sk 5xxe, 1 control terminals, Bus parameters sk 5xxe – NORD Drivesystems BU0020 User Manual

Page 61: Control terminals, 6 parameterisation, P480, Function busio in bits

Advertising
background image

6 Parameterisation

BU 0020 GB-2612

61

6.2 BUS Parameters SK 5xxE

Note

The SK 54xE frequency inverter can administer 5 setpoint or actual values. However,
the Profibus bus system can only process setpoint or actual values 1 ... 3 (PPO1 ...
PPO4).

Pos: 93 /Anleitungen/5. Parametrierung/5.5 Steuerklemmen @ 0\mod_1327678262854_388.docx @ 9027 @ 3 @ 1

6.2.1 Control terminals

Parameter
{factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

Pos: 94 /Anleitungen/5. Parametrierung/Parameter/P400-P499/Parameter P480

– Funktion Bus I/O In Bits @ 0\mod_1328002641156_388.docx @ 10779 @ @ 1

P480

[-01]

...

[-12]

Function BusIO In Bits

(Function Bus I/O In Bits)

S

0 ... 74

{ all 0 }

The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions
(P420...425).

In order to use this function, one of the bus setpoints (P546, P547, P548) must be set to >Bus I/O
In Bits 0-7 <. The required function must then be assigned to the relevant bit.

With the SK 54xE in association with IO extension modules (e.g. SK TU4-IOE) these I/O bits can
also process their input signals.

[-01] = Bus I/O In Bit 0 (or SK54xE and above: + DI1 of the second SK xU4-IOE)

[-02] = Bus I/O In Bit 1 (or SK54xE and above: + DI2 of the second SK xU4-IOE)

[-03] = Bus I/O In Bit 2 (or SK54xE and above: + DI3 of the second SK xU4-IOE)

[-04] = Bus I/O In Bit 3 (or SK54xE and above: + DI4 of the second SK xU4-IOE)

[-05] = Bus I/O In Bit 4 (or SK54xE and above: + DI1 of the first SK xU4-IOE)

[-06] = Bus I/O In Bit 5 (or SK54xE and above: + DI2 of the first SK xU4-IOE)

[-07] = Bus I/O In Bit 6 (or SK54xE and above: + DI3 of the first SK xU4-IOE)

[-08] = Bus I/O In Bit 7 (or SK54xE and above: + DI4 of the first SK xU4-IOE)

[-09] = Flag 1

[-10] = Flag 2

[-11] = Bit 8 BUS control word

[-12] = Bit 9 BUS control word

The possible functions for the Bus In Bits can be found in the table of functions for the digital
inputs P420...425.

For further details, please refer to the manual for the AS interface, BU 0090.

Pos: 95 /Anleitungen/5. Parametrierung/Parameter/P400-P499/Parameter P481

– Funktion Bus I/O Out Bits @ 0\mod_1328002703095_388.docx @ 10802 @ @ 1

Advertising