3 information, Information, 6 parameterisation – NORD Drivesystems BU0020 User Manual

Page 67: P740, Pzd bus in

Advertising
background image

6 Parameterisation

BU 0020 GB-2612

67

6.2.3 Information

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter set

Pos: 113 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P740

– Prozessdaten Bus In [bis SK 535E] @ 0\mod_1328175248086_388.docx @ 13313 @ @ 1

P740

[-01]

...

[-13]

PZD bus in

(Process data bus in)

up to SK 535E

S

0000 ... FFFF (hex)

This

parameter

informs

about the actual control
word and the setpoints that
are transferred via the bus
systems.

For display, a BUS system
must be selected in P509

[-01 ] = Control word

Control word, source from
P509.

[-02] = setpoint value 1
[-03] = setpoint value 2
[-04] = setpoint value 3

Setpoint data from main
setpoint (P510 [-01]).

[-05] = Bus I/O In Bits (P480)

The displayed value depicts all
Bus In bit sources linked with
OR.

[-06 ] = Parameter data In 1
[-07 ] = Parameter data In 2
[-08 ] = Parameter data In 3
[-09 ] = Parameter data In 4
[-10 ] = Parameter data In 5

Data during parameter transfer:
Order label (AK),
 Parameter
number (PNU),
 Index (IND),
Parameter value (PWE 1/2)

[-11] = setpoint value 1
[-12] = setpoint value 2
[-13] = setpoint value 3

Setpoint data from the master
function value (Broadcast), if
P509 = 9/10(P510 [-02])

Pos: 114 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P740

– Prozessdaten Bus In [ab SK 540E] @ 0\mod_1328177837899_388.docx @ 13336 @ @ 1

P740

[-01]

...

[-23]

PZD bus in

(Process data bus in)

SK 540E and

above

S

0000 ... FFFF (hex)

This

parameter

informs

about the actual control
word and the setpoints that
are transferred via the bus
systems.

For display, a BUS system
must be selected in P509

[-01 ] = Control word

Control word, source from
P509.

[-02] = setpoint value 1
[-03] = setpoint value 2
[-04] = setpoint value 3
[-05] = setpoint value 4
[-06] = setpoint value 5

Setpoint data from main
setpoint (P510 [-01]).

[-07] = Bus I/O In Bits (P480)

The displayed value depicts all
Bus In bit sources linked with
OR.

[-08 ] = Parameter data In 1
[-09 ] = Parameter data In 2
[-10 ] = Parameter data In 3
[-11 ] = Parameter data In 4
[-12 ] = Parameter data In 5

Data during parameter transfer:
Order label (AK),
 Parameter
number (PNU),
 Index (IND),
Parameter value (PWE 1/2)

[-13] = setpoint value 1
[-14] = setpoint value 2
[-15] = setpoint value 3
[-16] = setpoint value 4
[-17] = setpoint value 5

Setpoint data from the master
function value (Broadcast), if
P509 = 9/10(P510 [-02])

[-18] = PLC control word

Control word, source PLC

[-19] = setpoint value 1
[-20] = setpoint value 2
[-21] = setpoint value 3
[-22] = setpoint value 4
[-23] = setpoint value 5

Setpoint data from the PLC.

Pos: 115 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P741

– Prozessdaten Bus Out [bis SK 535E] @ 0\mod_1328177890266_388.docx @ 13359 @ @ 1

Advertising