Internal status machine – NORD Drivesystems BU0020 User Manual

Page 82

Advertising
background image

PROFIBUS DP

– Supplementary manual options for NORD - Frequency Inverters

82

BU 0020 GB-2612

Sw itch-on

disabled

Ready for

sw itch-on

Activated

Operation

enabled

Emergency stop

active

Error reaction

active

Error

From any device status

3

4

5

6

8

4

5

5

Not on standby

Sw itching on the inverter

Loading relay applied

Error

Error reaction complete

Bit0 = 0:

Shut dow n

& Bit1 = 1:

Enable voltage

& Bit2 = 1:

Enable pulses

(xxxx x1xx xxxx x110)

Bit 3 = 0:

Disable operation

Bit0 = 1:

Sw itch on

Bit3 = 1:

Enable operation

Bit2 = 0:

Emergency stop

Bit1 = 0:

Disable voltage

v Bit2 = 0:

Emergency stop

Priority of control com m ands:
1. Disable / enable voltage
2. Emergency stop
3. Shut dow n
4. Enable operation
5. Sw itch on
6. Disable operation
7. Reset error

Coding of status:
1: Bit 0 = 0
2: Bit 6 = 1
3: Bit 0 = 1
4: Bit 1 = 1
5: Bit 2 = 1
6: Bit 5 = 0
7: Bit 2 & Bit 3 = 1
8: Bit 3 = 1

3

5

2

3

3

6

4

2

2

1

2

3

7

8

f = 0 reached
(emergency stop complete)

Bit7 0

1

Error acknow ledgement

Control bits
0. Standby / Shut dow n
1. Disable / enable voltage
2. Enable pulses / emergency stop
3. Disable / enable operation
4. Betriebsbedingung / HLG sperren
5. Enable / stop RUE
6. Enable / disable setpoint
7. Error acknow ledgement (0

1)

10. Control data valid / invalid

11. Direction of rotation clockwise
12. Direction of rotation anticlockwise
14. Parameter set Bit 0
15. Parameter set Bit 1

4

5

6

Bit4 = 0:

Move dow n emergency stop ramp and

remain in 'Operation enabled'

Bit5 = 0:

Hold frequency

Bit6 = 0:

Setpoint = 0%

Bit0 = 0:

Shut dow n

5

Bit3 = 1:

Enable operation

& Bit0 = 1

: Sw itch on

2

Internal status machine