P745

Option version

(Module version)

0.0 ... 999.9

Version status (software version) of the technology unit (SK TU3-xxx), but only when own
processor is present, therefore not for SK TU3-CTR.

Have this data available if you have a technical query.

Pos: 118 /Anleitungen/5. Parametrierung/Parameter/P700-P799/Parameter P746

– Baugruppen Zustand [SK 5xxE] @ 1\mod_1335793579623_388.docx @ 25168 @ @ 1

P746

Module status

(Module status)

S

0000 ... FFFF (hex)

Shows the actual status (readiness, error, communication) of the technology unit (SK TU3-xxx),
but only when own processor is present, i.e. not for SK TU3-CTR.

Example:

0603

hex

High byte = 06

hex

 Profibus

Low byte = 03

hex

 Module ready + connection to master

Details of the codes specific to the bus can be found in the section "Error monitoring" of the
relevant supplementary instructions.