HP XP Continuous Access Software User Manual

Page 106

Advertising
background image

• Remote array's serial number.
• Remote array's controller ID.

NOTE:

The controller ID for an XP12000/XP10000 is 4.

• Path group ID. The path group ID is within the range of 1-FF (hexadecimal). Up to 64 path

group IDs can be registered per array.

NOTE:

In the current version, the path group IDs always take the default values and cannot be changed.

8.

In the Add DKC pane, select a primary and remote array port to configure a logical path.

9.

Click Option.

10.

In the DKC Option pane, configure the logical path and array options. For more information, see

Changing options for logical paths and arrays

.

11.

Click Set to close the DKC Option pane.

12.

In the Preset list, check the settings you made.
• To modify a setting, right-click the setting from the Preset list, and select Modify. A pane

appears where you can modify the setting.

• To cancel a setting, right-click the setting in the Preset list, and select Cancel.

13.

Click Apply to apply the settings.

NOTE:

If an error occurs, the right-most column of the Preset list displays the error code. To view

detailed information about the error, right-click the error code, and select Error Detail. An

error message appears providing detailed information about the error.

106

Configuring arrays and logical paths